pntmoni Monthly Report
QZSS CLAS performance evaluation — Rapid (R5)
1 Revision History
| Version | Date | Notes |
|---|---|---|
| 1.0 | 2026-10-21 | Initial edition |
| 1.1 | 2026-10-21 | Brand written as pntmoni; subtitle and summary-table layout aligned with the website. No change to evaluation figures |
Rapid edition: this report uses the GSI Rapid series (R5.1 from 2026-04 onward, R5 before that) as the reference coordinates. The Rapid series is a quick-look solution published 2–3 days after observation. A final edition based on the Final series (F5/F5.1, published ~3 weeks after observation) is planned as a free national-aggregate report around the end of the following month, and will supersede these rapid values; a per-station detailed edition based on F5 is planned for the paid plan. Until then this rapid edition is the current evaluation.
Rapid-vs-Final differences are usually at the mm level, but can widen briefly right after events such as earthquakes or equipment changes (methodology §3.2 / §8.5).
2 Introduction
This report summarises pntmoni’s evaluation of QZSS CLAS (Centimeter Level Augmentation Service) performance for September 2026, using publicly available data and open-source tooling.
As an independent evaluation service for GNSS augmentation, pntmoni continuously monitors CLAS performance at higher spatial and temporal resolution than the official Service Performance Report published by the Cabinet Office / Quasi-Zenith Satellite System Services Inc. (QSS). This monthly report complements the official semi-annual report, offering monthly cadence, an independent third-party assessment, and practically useful analytical depth. This Free-tier monthly report covers national statistics only; per-station analysis is provided in the Pro tier.
The “Methodology Version Tag” at the end of this report uniquely identifies the processing configuration that produced it. For the full methodology document see [https://pntmoni.com/methodology/clas/v1.1.0](https://pntmoni.com/methodology/clas/v1.1.0).
3 Methodology
This section summarises the methodology; see the link above for the full document.
Data sources: 30-second RINEX observations from ~1,300 GEONET stations distributed by the Geospatial Information Authority of Japan (GSI) under PDL 1.0 (source: GSI GEONET data service), the CLAS L6 augmentation archive published on the web by QSS, and IGS broadcast ephemerides / Earth-rotation parameters from CDDIS.
Processing engine: pntmoni-claslib v0.8.3-pntmoni-1, PPP-RTK mode (kinematic, l1+l2+l5).
Reference coordinates: GSI daily coordinate solutions (the series matching the period — F5 era = ITRF2014, F5.1 era = ITRF2020; R5 / R5.1 when the Rapid series is used) are relativised to station 92110 (Tsukuba 1) and smoothed with a ±7-day (15 calendar-day) median filter centred on the target day \(d\) (common-mode removal, Method B). Method version: gsi-daily-median15d-1.1.
Quality control (QC): teqc 2019Feb25 for 2026–2027, with migration to MRTKLIB’s mrtk qc planned around 2027/Q4.
Statistical aggregation: 95% / 99% percentile errors are computed by pooling the epoch errors of all stations and all days in each aggregation cell (methodology §5.1, same rule as NAVIGATION 2026). TTFF uses a 15-minute reset (continuity with NAVIGATION 2026, methodology §5.2); a 60-minute reset is planned.
Known structural differences from official QSS figures: pntmoni’s methodology differs structurally from the official QSS Service Performance Report in four respects — sampling rate (30 s vs 1 s), a parameter set retuned for 30 s, CLASLIB version differences, and the resulting Kalman-filter behaviour. See Shiono & Kubo (2025, 2026). These are treated as structural characteristics, not bugs; comparing absolute values or equating the numbers is not meaningful (methodology §8.3). In direction, the lower epoch density at 30 s gives filter convergence and re-convergence intervals a relatively larger weight in the pooled statistics, pushing the tail percentiles (95% / 99%) above the official evaluation. PS-QZSS standard values are accordingly used in this report as reference values only, never for compliance judgement (see the note in the Executive Summary).
3.1 Evaluation Network
CLAS divides the country into 12 networks; each station’s network is determined by the Compact Network ID assigned by CLASLIB. Stations are further classified as Inside Network or Outside Network by a point-in-polygon test against the per-network polygons defined in the ION GNSS+ 2025 / NAVIGATION 2026 papers (Shiono & Kubo) — i.e. regions where augmentation is interpolated vs extrapolated. The network polygons below are updated only when the CLAS service area changes (rarely); the polygon version is recorded in the Methodology Version Tag at the end of this report.
Figure 1: CLAS 12-network grid points and the GEONET stations evaluated this month.
The CLAS network polygons define the regions where the augmentation is intended to meet spec. Outside-Network stations receive corrections derived by extrapolation and may therefore have different error characteristics (Inside/Outside aggregate analysis is provided in the Pro tier).
4 Executive Summary
| Metric | Value |
|---|---|
| Stations evaluated | 1,154 |
| Horizontal error 50% [cm] | 2.56 |
| Horizontal error 95% [cm] | 12.91 |
| Horizontal error 99% [cm] | 26.53 |
| Vertical error 95% [cm] | 23.34 |
| TTFF 50% [s, 15-min reset] | 180.0 |
| TTFF 95% [s, 15-min reset] | 300.0 |
| National fix rate (Q=4) | 93.9 % |
Highlights for September 2026:
- National horizontal error, 95th percentile: 12.91 cm
- National vertical error, 95th percentile: 23.34 cm
- TTFF (15-min reset, 95th percentile): 300.0 s
- National fix rate (Q=4): 93.88%
- L6 broadcast alerts: 0
The QZSS Performance Standard (PS-QZSS) sets the CLAS kinematic positioning-accuracy standard at horizontal 95% 12 cm / vertical 95% 24 cm. Compliance with the standard is verified by QSS’s official Service Performance Reports, whose evaluation is run under conditions that differ from this report’s (1-s sampling, a fixed evaluation station set). pntmoni’s 30-s, ~1,100-station methodology (see Methodology) is known to produce structurally higher tail percentiles than the official evaluation (Shiono & Kubo 2026, §4.1.2). Whether a value in this report sits above or below a PS-QZSS standard value is therefore not a compliance judgement; the standard values appear in this report only as a reference scale (e.g. in the spatial distribution maps). Quantitative reconciliation against official figures is performed in the half-yearly Comparison Archive.
5 Performance
5.1 National Overview
5.1.1 Error Distribution
Figure 2: Cumulative distribution of horizontal error (epochs pooled over qualified stations).
Figure 3: Cumulative distribution of vertical error (epochs pooled over qualified stations).
| Percentile | TTFF [s] |
|---|---|
| 50% | 180.0 |
| 90% | 240.0 |
| 95% | 300.0 |
| 99% | 510.0 |
September 2026: TTFF success rate 98.21 % (108,236/110,208 reset windows obtained a valid fix). At each reset the filter state is fully cleared and the solution re-initialized to standalone; TTFF is the time from that reset to the first fixed solution, recorded on the 30-second observation grid. A fix at the first epoch after reset is therefore recorded as 0 s (true TTFF ≤ 30 s), which is why P50/P95 are often 0 s; P99 reflects the convergence tail.
Figure 4: Cumulative distribution of TTFF (15-min reset, reset windows pooled nationwide over the period).
5.1.2 Spatial Distribution
Performance is visualised on hexagonal cells sized to the CLAS augmentation grid spacing (~60 km). Each cell’s value is the 95th percentile computed over all stations and all epochs pooled within that cell (same rule as methodology §5.1). Cells with no stations remain blank. Cells backed by fewer than 3 distinct stations are drawn with a dotted inner ring — a reliability marking: with so few stations the cell’s percentile is statistically thin and station-local effects (multipath environment, antenna snow accretion) can colour the whole cell, so read those cells as indicative rather than representative (methodology §5.1, 2026-07-18 revision). Southern-island stations outside the CLAS service area (out_of_service) are excluded from cell evaluation.
Colour encodes error magnitude on a perceptually-uniform continuous colormap (purple = smaller error → yellow = larger error), with no discrete boundaries — the map shows the spatial gradient of performance, not a pass/fail classification. The scale spans a fixed range (0–40 cm horizontal, 0–60 cm vertical) set from pntmoni’s own historical error range, so maps stay comparable month to month; this range is not a Performance-Standard threshold and the colouring is not a compliance judgement (see Methodology and the Executive Summary note). Cells exceeding the range render at the top colour (colorbar top arrow).
Figure 5: Spatial distribution of the horizontal-error 95th percentile (60 km hex cells, epochs pooled). Dotted ring = cell backed by fewer than 3 stations (indicative).
Figure 6: Spatial distribution of the vertical-error 95th percentile (60 km hex cells, epochs pooled). Dotted ring = cell backed by fewer than 3 stations (indicative).
5.1.3 Recent-Month Trend
Coming Soon. This section will show the past 13 months of national 95th-percentile horizontal/vertical error, with the current month highlighted and a comparison marker for the same month last year. The trend view becomes meaningful once the backfill has filled in everything from April 2025 onward; until then the table above shows the current month’s values only.
5.2 Cross-Validation
Coming Soon
Cross-validation will report agreement statistics between the primary CLASLIB-based processing and the parallel evaluation engine MRTKLIB on a sample of ~100 stations. It demonstrates that pntmoni’s evaluation agrees across independent OSS implementations, in preparation for making MRTKLIB primary in 2027/Q4.
Next: publish cross-validation on the parallel sample stations. Planned for 2027/Q4: role reversal — MRTKLIB primary, CLASLIB as historical reference.
6 Data Availability
6.1 Overview
Figure 7: Distribution of data availability across stations.
National-statistics availability for September 2026: 93.9%.
GEONET maintenance events affecting availability: no major maintenance events are recorded for September 2026.
For the latest GEONET maintenance notices see GSI’s official notices page (https://terras.gsi.go.jp/).
7 Anomaly Detection
7.1 L6 Broadcast Alerts
The L6 broadcast Alert flag, carried in the CLAS augmentation stream (CSSR data part), signals a known issue detected on the generation side. This section aggregates it monthly to surface the broadcaster’s self-reported health.
September 2026: 0 alerts across all L6 broadcasts (no message had the Alert flag set).
7.2 Crustal Deformation Events
An earthquake large enough to displace a GEONET station breaks the continuity of that station’s GSI daily-solution series. Because the reference coordinate is the denominator of every error metric in this report, the affected station-days are withheld rather than reported against a reference that straddles the discontinuity. Events are identified from JMA earthquake information and confirmed on the daily solutions themselves; a candidate is an event with only a few displaced stations, or an aftershock whose step estimate carries postseismic motion — it is excluded all the same and re-examined when the Final edition is produced.
September 2026: no co-seismic offset event was catalogued, so no station-day was withheld on this ground.
8 Appendix
8.1 GNSS System Notices: NAGU / NANU / NAQU
Notices issued against GNSS constellation operations during September 2026, recorded for cross-referencing against anomaly events and signal availability.
| Date | Satellite | Notice | Type | Severity |
|---|---|---|---|---|
| 2026-09-01 10:00 UTC | QZS | NAQU 2026232, NAQU 2026238 | scheduled_maintenance | partial |
| 2026-09-06 04:59 UTC | QZS PRN199 | NAQU 2026235, NAQU 2026248 | scheduled_maintenance | total |
| 2026-09-02 05:54 UTC | GAL | NAGU 2026042, NAGU 2026043, NAGU 2026044 | other | informational |
| 2026-09-02 20:35 UTC | GPS PRN13 | NANU 2026067 | other | total |
| 2026-09-02 21:54 UTC | GPS PRN25 | NANU 2026068, NANU 2026069 | other | total |
| 2026-09-02 09:46 UTC | QZS | NAQU 2026240 | unscheduled_outage | partial |
| 2026-09-02 09:46 UTC | QZS PRN204 | NAQU 2026242 | unscheduled_outage | partial |
| 2026-09-02 09:46 UTC | QZS PRN209 | NAQU 2026243 | unscheduled_outage | partial |
| 2026-09-02 09:46 UTC | QZS PRN205 | NAQU 2026244 | unscheduled_outage | partial |
| 2026-09-02 09:46 UTC | QZS PRN206 | NAQU 2026245 | unscheduled_outage | partial |
| 2026-09-11 02:45 UTC | GPS PRN23 | NANU 2026070, NANU 2026072 | scheduled_maintenance | total |
| 2026-09-14 21:59 UTC | QZS PRN200 | NAQU 2026249, NAQU 2026250 | scheduled_maintenance | total |
| 2026-09-15 18:45 UTC | GPS PRN13 | NANU 2026071, NANU 2026074 | scheduled_maintenance | total |
| 2026-09-18 03:00 UTC | GPS PRN1 | NANU 2026073, NANU 2026075 | scheduled_maintenance | total |
| 2026-09-24 23:45 UTC | GPS PRN15 | NANU 2026076, NANU 2026078 | scheduled_maintenance | total |
| 2026-09-29 06:59 UTC | QZS PRN199 | NAQU 2026251, NAQU 2026253 | scheduled_maintenance | total |
| 2026-09-29 22:00 UTC | GPS PRN25 | NANU 2026077, NANU 2026080 | scheduled_maintenance | total |
September 2026: 17 notice(s) detected. Collected from the official NAGU (Galileo), NANU (GPS) and NAQU (QZSS) notices.
8.2 List of Satellites
A snapshot of the constellation operators’ official pages (state at fetch time). Sources: GPS = USCG NAVCEN, QZSS = QSS DoD, Galileo = GSC Europa.
Fetched at: 2026-10-05 12:06 UTC
8.2.1 GPS
| PRN | SVN | Block | Slot | Clock | Status | Notice |
|---|---|---|---|---|---|---|
| G16 | 56 | IIR | B1 | RB | Operational | FCSTSUMM 2025066 |
| G29 | 57 | IIR-M | C1 | RB | Operational | FCSTSUMM 2026063 |
| G02 | 61 | IIR | D1 | RB | Operational | FCSTSUMM 2026031 |
| G24 | 65 | IIF | A1 | RB | Operational | FCSTSUMM 2026064 |
| G03 | 69 | IIF | E1 | RB | Operational | FCSTSUMM 2026054 |
| G32 | 70 | IIF | F1 | RB | Operational | FCSTDV 2026047 |
| G31 | 52 | IIR-M | A2 | RB | Operational | FCSTSUMM 2026021 |
| G15 | 55 | IIR-M | F2 | RB | Operational | FCSTSUMM 2026078 |
| G25 | 62 | IIF | B2 | RB | Operational | FCSTSUMM 2026080 |
| G27 | 66 | IIF | C2 | RB | Operational | FCSTSUMM 2026043 |
| G10 | 73 | IIF | E2 | RB | Operational | FCSTSUMM 2025002 |
| G01 | 80 | III | D2 | RB | Operational | FCSTSUMM 2026075 |
| G22 | 44 | IIR | B3 | RB | Operational | FCSTSUMM 2026036 |
| G05 | 50 | IIR-M | E3 | RB | Operational | FCSTMX 2026082 |
| G30 | 64 | IIF | A3 | RB | Operational | FCSTSUMM 2025087 |
| G09 | 68 | IIF | F3 | RB | Operational | FCSTSUMM 2026017 |
| G08 | 72 | IIF | C3 | RB | Operational | FCSTSUMM 2025038 |
| G07 | 48 | IIR-M | A4 | RB | Operational | FCSTMX 2026081 |
| G17 | 53 | IIR-M | C4 | RB | Operational | FCSTSUMM 2026046 |
| G12 | 58 | IIR-M | B4 | RB | Operational | FCSTDV 2026083 |
| G06 | 67 | IIF | D4 | RB | Operational | FCSTDV 2025090 |
| G04 | 74 | III | F4 | RB | Operational | FCSTDV 2025073 |
| G20 | 82 | III | F5 | RB | Operational | FCSTSUMM 2026033 |
| G19 | 59 | IIR | C5 | RB | Operational | FCSTSUMM 2026066 |
| G26 | 71 | IIF | B5 | RB | Operational | FCSTSUMM 2026056 |
| G23 | 76 | III | E5 | RB | Operational | FCSTSUMM 2026072 |
| G11 | 78 | III | D5 | RB | Operational | UNUSABLE 2026049 |
| G13 | 83 | III | A5 | RB | Operational | FCSTSUMM 2026074 |
| G21 | 81 | III | E6 | RB | Operational | FCSTSUMM 2026040 |
| G18 | 75 | III | D6 | RB | Operational | FCSTSUMM 2024042 |
| G14 | 77 | III | B6 | RB | Operational | FCSTSUMM 2025054 |
| G28 | 79 | III | A6 | RB | Operational | UNUSABLE 2026044 |
8.2.2 QZSS (Michibiki)
| PRN | SVN | Block | Signals | Status | Notice |
|---|---|---|---|---|---|
| J194 | 002 | Ⅱ-Q | L1C/A, L1C, L2C, L5, L1S, L5S, L6D, L6E | Operational | |
| J199 | 003 | Ⅱ-G | L1C/A, L1C, L2C, L5, L1S, L5S, L1Sb, L6D, L6E, Sr/Sf | Operational | |
| J195 | 004 | Ⅱ-Q | L1C/A, L1C, L2C, L5, L1S, L5S, L6D, L6E | Operational | |
| J196 | 005 | ⅡA-Q | L1C, L2C, L5, L1C/B, L1S, L5S, L6D, L6E | Operational | |
| J200 | 007 | Ⅲ-G | L1C, L5, L1C/B, L5S, L1Sb, L6D, L6E | Operational | |
| J201 | 008 | Ⅲ-G | L1C, L5, L1C/B, L5S, L1Sb, L6D, L6E | Outage |
8.2.3 Galileo
| E# | GSAT | Clock | Status | Notice |
|---|---|---|---|---|
| E11 | GSAT0101 | RAFS | Operational | |
| E12 | GSAT0102 | RAFS | Operational | |
| E19 | GSAT0103 | RAFS | Operational | |
| E18 | GSAT0201 | PHM | Unusable | GENERAL 2021008 |
| E14 | GSAT0202 | RAFS | Unusable | GENERAL 2021008 |
| E26 | GSAT0203 | PHM | Operational | |
| E22 | GSAT0204 | RAFS | Unusable | GENERAL 2017045 |
| E30 | GSAT0206 | PHM | Operational | |
| E07 | GSAT0207 | PHM | Operational | |
| E08 | GSAT0208 | PHM | Operational | |
| E09 | GSAT0209 | RAFS | Operational | |
| E01 | GSAT0210 | RAFS | Unusable | GENERAL 2023048 |
| E02 | GSAT0211 | PHM | Operational | |
| E03 | GSAT0212 | PHM | Operational | |
| E04 | GSAT0213 | RAFS | Operational | |
| E05 | GSAT0214 | PHM | Operational | |
| E21 | GSAT0215 | PHM | Operational | |
| E25 | GSAT0216 | PHM | Operational | |
| E27 | GSAT0217 | PHM | Operational | |
| E31 | GSAT0218 | PHM | Operational | |
| E36 | GSAT0219 | PHM | Operational | |
| E13 | GSAT0220 | PHM | Operational | |
| E15 | GSAT0221 | PHM | Operational | |
| E33 | GSAT0222 | PHM | Operational | |
| E34 | GSAT0223 | PHM | Operational | |
| E10 | GSAT0224 | PHM | Operational | |
| E29 | GSAT0225 | PHM | Operational | |
| E23 | GSAT0226 | PHM | Operational | |
| E06 | GSAT0227 | PHM | Operational | |
| E16 | GSAT0232 | PHM | Operational | |
| E28 | GSAT0233 | PHM | Operational | |
| E32 | GSAT0234 | PHM | Operational |
pntmoni’s evaluation also covers the Galileo signals received at GEONET stations.
8.3 Methodology Version Tag
| Item | Value |
|---|---|
| Methodology version | 1.1.0 |
| Pipeline config hash | 8f6422e9b5b433ec |
| Engine | pntmoni-claslib v0.8.3-pntmoni-1 |
| QC tool | teqc 2019Feb25 |
| Reference-coordinate method version | gsi-daily-median15d-1.1 |
| Evaluation stream | rapid |
| Reporting period | September 2026 |
| Data mode | live |
For the full methodology document see [https://pntmoni.com/methodology/clas/v1.1.0](https://pntmoni.com/methodology/clas/v1.1.0).